SanDisk Industrial Grade CompactFlash 5000 Product Manual
© 2007 SanDisk® Corporation 43 July 2007
4.5.10
Device Control Register
(Address–3F6[376]; Offset Eh)
This register is used to control the CompactFlash Memory Card interrupt
request and to issue an ATA soft reset to the card. The bits are defined as
follows:
D7 D6 D5 D4 D3 D2 D1 D0
X X X X 1 SW Rst -IEn 0
Bit Name Description
D7 X Irrelevant.
D6 X Irrelevant.
D5 X Irrelevant.
D4 X Irrelevant.
D3 1 Bit ignored by the card.
D2 SW Rst Set to 1 in order to force the card to perform an AT Disk controller
Soft Reset operation. This does not change the PCMCIA Card
Configuration registers as a hardware reset does. The card
remains in Reset until this bit is reset to “0”.
D1 -IEn Interrupt Enable bit enables interrupts when the bit is 0. When the
bit is 1, interrupts from the card are disabled. This bit also controls
the Int bit in the Configuration and Status Register. This bit is set
to 0 at power on and reset.
D0 ERR Bit ignored by the card.
4.5.11
Card (Drive) Address Register (Address–3F7[377];
Offset Fh)
This register is provided for compatibility with the AT disk drive interface. This
register should not be mapped into the host's I/O space because of potential
conflicts on Bit 7. The bits are defined as follows:
D7 D6 D5 D4 D3 D2 D1 D0
X -WTG -HS3 -HS2 -HS1 -HS0 -nDS1 -nDS0
Bit Name Description
D7 X This bit is unknown. Implementation Note: Conflicts may occur on the host data
bus when this bit is provided by a Floppy Disk Controller operating at the same
addresses as the CompactFlash Memory Card. Following are some possible
solutions to this problem for the PCMCIA implementation:
1)
Locate the CompactFlash Memory Card at a non-conflicting address, i.e.,
Secondary address (377) or in an independently decoded Address Space
when a Floppy Disk Controller is located at primary addresses.
2)
Do not install a Floppy and a CompactFlash Memory Card in the system at
the same time
3)
Implement a socket adapter that can be programmed to (conditionally) tri-
state D7 of I/0 address 3F7/377 when a CompactFlash Memory Card is
installed and conversely to tri-state D6-D0 of I/O address 3F7/377 when a
floppy controller is installed
4)
Do not use the card's Drive Address Register. This can be accomplished by
either programming the host adapter to enable only I/O addresses 1F0-1F7,
Vista de pagina 49